The new full rate LEDR microwave radio family provides full duplex, scalable bandwidth and capacity from 1 x E1 (2.048 Mbps) in a 500 kHz channel or 3 x E1 (6.144 Mbps) in a 2 MHz channel. These radios are designed to operate in a point to point environment with a wide range of applications. They are especially effective for telecommunications access and transport links, and for use as backhauls to extend existing telecommunication channels. The full rate LEDR microwave radio is designed to connect to any industry standard E1 G.703 source.

Features

  • Frequency Range: 1350 MHz to 1535 MHz
  • Data Rates:1 x E1 or 3 x E1
  • Spectrally Efficient: 32 QAM, 64 QAM *
  • Excellent Sensitivity:Better than –90 dBm @10 -6 BER at 1 x E1
  • Advanced Modem Features: FEC, Interleaver and Adaptive Equalizer
  • Front Panel Displays for Easy Maintenance and Link Monitoring
  • Built-in NMS Element Manager
  • SNMP Network Management for Fault, Configuration, Performance and Security Management
  • Integrated HTML web server allows networkwide management via the Internet
  • Built in 9600 bps Data Service Channel
  • Local Loopback and Remote Loopback
  • 8 Relay Alarm Contacts per Radio
  • DTMF Compatible Orderwire
  • Optional 1+1 hot or warm stand-by protected configuration
  • Optional space diversity configuration

* Consult Factory

More Information


Specifications

General
Frequency Range: 1350-1535 MHz
RF Channel Bandwidth: 500 kHz or 2.0 MHz
User Data Rates: Fractional E1/T1
1 x E1 (2 Mbps)
3 x E1 (6 Mbps)
Modulation Type: 32 QAM,64 QAM *
FEC: Reed Solomon
Temperature Range: –10° to 50° C
Humidity: < 95% non-condensing
Voltage Range: ±24 Vdc,or ±48 Vdc (±20%)
Power Consumption: Non-Protected:<60 W,Protected:<135 W
Size: 4.5cm (1U) x 48cm x 30cm
1.75in x 19in x 12in


System Performance
Channel Spacing 500 kHz 2.0 MHz
Capacity 1 x E1 3 x E1
Receiver Sensitivity
(10-6 BER)1 (32 QAM)
-90 dBm -85 dBm
System Gain
(10 -6 BER) (32 QAM)
120 dB 115 dB
1. Receiver sensitivity for 10-3 BER are typically 3 dB better
2. Additional overhead channels over and above capacity shown


Transmitter
Power Output at antenna port: +30 dBm (32 QAM)
Output Control Range: 10 dB in 10 steps
Frequency Stability: 1.5 ppm
Spurious Outputs: exceeds ETSI specifications <-80 dBc


Receiver
Residual BER: < 1x10-10
Dynamic Range: > 65 dB


Interfaces
Data: G.703
Orderwire: DTMF capable
Data Service Channel: RS-232, 9600 bps
Ethernet NMS: 10 Base-T
Console Port: RS-232, 300 bps to 115.2 kbps
Alarms: 4 programmable outputs,
4 programmable inputs
Antenna: 50 Ohms Impedance


Options
  • Space Diversity
  • Hot-standby Protected
  • Bandwidth Upgrade Kits (consult factory for details)
  • Bandpass Duplexers
  • Integrated Multiplexers (see separate specification sheet)


Network Management
Local LED Indicators: Front Panel LED status indicate: Power, Active, General Alarm, Rx Alarm, Tx Alarm, I/O Alarm.
Front Panel LCD: Display & keypad for management of local & remote radio.
Element Management: Full management of LEDR network via command line interface.
SNMP Management: Full IP-based management of LEDR network and SNMP-enabled peripherals via custom enterprise MIB
HTML Webserver: Full IP-based management of LEDR network and web-enabled peripherals via any web browser (e.g. Netscape™ or Internet Explorer™)


Accessories
  • 110/240 Vac, 50/60 Hz Power Supply
  • Orderwire Handset
  • G.703 120 Ohms to 75 Ohms balun


Protected
Configuration: 2 x LEDR radios, connected via protected switch box
Total Size: 2 x 1 RU high + 1 x 2 RU high
Transmit Branching Loss: 2 dB
Receive Branching Loss: 5 dB
Receive Switching: Hitless


Agency Approvals for LEDR 1400F
Transmission: ETS 300 630, MPT 1717 Class 3
Environmental: ETS 300 019, Class 3.2
EMC: ETS 300 385
Safety: CE Mark

* Consult Factory